Détails sur le produit:
Conditions de paiement et expédition:
|
| Nom: | Analyse thermogravimétrique Tga Gravimètre thermique Tg Gravimètre thermique Tga Fabricant | Plage de température: | Température ambiante ~ 1550 ℃ |
|---|---|---|---|
| Résolution de la température: | 0,01 ℃ | Fluctuation de la température: | ± 0,1 ℃ |
| Taux de chauffage: | 0,1 ~ 100 ℃ / min | Plage de mesure de la balance: | 0.01 mg ≈ 3 g, peut être élargi à 30 g |
| Est il personnalisable: | Personnalisable | Modèle: | ZL-3047B |
| Mettre en évidence: | Thermogravimetric Analysis TGA machine,Thermal Gravimeter TG analyzer,Rubber Testing TGA equipment |
||
Instrument Introduction:
Thermogravimetric analysis (TG, TGA) is to observe the change of sample mass with temperature or time during the process of heating, constant temperature or cooling, with the purpose of studying the thermal stability and composition of the material.
It is widely used in research and development, process optimization and quality monitoring in various fields such as plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials.
Applications:
![]()
ZL-3047BMeasure and Study The Following Properties Of The Material
| Thermal Stability | Decomposition Process |
| Adsorption And Desorption | Oxidation And Reduction |
|
Quantitative Analysis of Ingredients |
Effects of Additives and Fillers |
| Moisture And Volatile Matter | Reaction Kinetics |
Performance Advantages:
The new furnace structure design, the upper cover design, is convenient for testing and placing samples. The furnace heating adopts double-row winding of precious metal alloy wire to reduce interference, high temperature resistance and anti-interference.
The tray sensor is made of precious metal alloy disc, which has the advantages of high temperature resistance, oxidation resistance and corrosion resistance.
Automatically switch the two-way atmosphere flow, fast switching speed and short stabilization time. At the same time, add one protective gas input.
Multi-stage temperature setting, using PID algorithm for precise control. Multi-stage heating and constant temperature are possible.
Bidirectional operating system, the instrument and computer can be operated synchronously, which greatly improves the efficiency of the experiment.
Software analysis, supporting analysis software, can accurately collect the changes of materials with temperature during the measurement process, collect spectra for data analysis.
7-inch color touch screen operation, comprehensive display information, high convenience of operation.
Power supply, circulation heat dissipation part and host are separated to reduce the influence of heat and vibration on the microthermal balance.
Technical Parameters:
| Technical Parameters |
Basic model ZL-TGA101 |
Upgrade model ZL-TGA103 |
Advanced model ZL-TGA105 |
| Temperature Range | Room temperature~1250℃ | Room temperature~1350℃ | Room temperature~1550℃ |
| Temperature Resolution | 0.01℃ | 0.01℃ | 0.01℃ |
| Temperature Fluctuation | ±0.1℃ | ±0.1℃ | ±0.1℃ |
| Heating Rate | 0.1~100℃/min | 0.1~100℃/min | 0.1~100℃/min |
![]()
Personne à contacter: Ms. Fiona Zhong